Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.12984288

- Product Categories
- Friendly Links
- home > Supply > Linear DC Power Supply 100V200A _ adjustable AC current source - Linear power supply
Information Name: | Linear DC Power Supply 100V200A _ adjustable AC current source - Linear power supply |
Published: | 2014-04-21 |
Validity: | 300 |
Specifications: | ACL2000 |
Quantity: | 1.00 |
Price Description: | |
Detailed Product Description: | Custom processing is the brand to Chroma Model DLC9000L Product Certification CCC input voltage (V) 380 Output Power (W) 10000 Output Voltage (V) 10000 Output Current (A) 10 Frequency Range (HZ) 0000 This power supply is three-phase input, high High Precision DC Power output up to 400kW. Accuracy, high accuracy, high stability, excellent electrical characteristics with ultra-high, the production line can provide ultra-low power ripple DC power supply, make our products more perfect performance. It has perfect protection circuit, to better meet the user simple, easy to use needs. Compared with the switching power supply, it has a high accuracy, small ripple, no high frequency radiation interference, for the occasion and so on. This power available capacitors, relays, resistors and other components for sophisticated test, can also be used as a thermistor, the motor and other electronic components experimental testing. Currently, many well-known manufacturers capacitors, resistors and other electronic components factory production units and scientific institutions, and other R & D units, are used in this series of power, were very high evaluation. Features 1, size range: Output voltage 0-700V, Output current 0-1000A, the output power is 0-6kW of optional 2, constant voltage constant current: voltage and current values ??from zero to rated continuously adjustable constant pressure constant flow automatically converted 3, overcurrent alarm: Alarm 0-120% of rated current continuously adjustable power output current exceeds the value of the current alarm sound and light alarm 4, overvoltage protection: 0-120% of rated voltage protection value continuous adjustable power supply output voltage will be tripping over voltage protection value protection 5, short circuit protection: Short circuit to allow long-term or short boot 6 in any working condition, overload: the power supply or the load fails, the output current exceeds the rating of 1.5 times, 7 power trip protection, short circuit alarm: When the output voltage is less than 1% of the rated power of sound and light alarm (optional) 8, automatic discharge: used for discharging the capacitive load shutdown (optional) 9, the output display: voltage, LED digital display while the current 10 pulse operation: time controller can be equipped with a DC pulse power constitute (optional) 11, intelligence: can be connected to a computer, consisting of computer-controlled intelligent power supply (optional) The main purpose of a foil , the guide pin formation, corrosion, enabling two tantalum, DC testing, aging; electric vehicle motor testing, aging of electronic devices to detect 3, resistors, relays, motors, etc., aging 4, electrolytic capacitors sophisticated, enabling tantalum capacitors 5 , resistors, relays, motors and other sophisticated electronic components, routine test 6, all other occasions the need to use a DC power supply specifications constant voltage constant current voltage and current values ??are available from 0 - Ratings continuously adjustable constant current constant state status automatically convert source effect CV ≤ 0.01% CC ≤ 0.01% (maximum output voltage, maximum current measurements) Load effect CV ≤ 0.1% CC ≤ 0.1% (the highest output voltage, maximum current measurements) ripple voltage CV ≤ 0.01% CC ≤ 0.1% (the highest output voltage, maximum current measurements) display voltmeter is 3 or 4 and a half meter LED digital display 3 or 4 half-LED digital display precision voltmeter 0.1V Ammeter 0.01 A (Note: The power display precision different specifications may be different) display error voltmeter ≤ 1% ± 1 word ammeter ≤ 1% ± 1 word (Note: You can adjust the display according to customer requirements error) Short circuit protection allowed under any circumstances Long-term Short-circuit protection overvoltage, overload, phase loss trip protection; over current alarm protection work long-term continuous operation at full load Input voltage three-phase 380V ± 10% 50Hz ± 10% Environmental conditions Temperature -20 ℃ - +40 ℃ Humidity ≤ 80 % Dear Customer Hello, if you need, please contact us directly or send an email to my company, please do not leave a message on this page, thank you! |
Admin>>>
You are the 8246 visitor
Copyright © GuangDong ICP No. 10089450, Shanghai to Mao Electronic Technology Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 8246 visitor
Copyright © GuangDong ICP No. 10089450, Shanghai to Mao Electronic Technology Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility